Mfg Part Number: E504 | Manufacturer: Microwave Engineering Corporation | NSN : 5985-00-632-0692 |
Item Name : coupler directional | CAGE Code : 06351 | FSC : 5985 Antennas Waveguides and Related Equipment |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-632-0692 Item Description: Coupler Directional | 5985 | 006320692 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
E504 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.750 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.400 INCHES NOMINAL |
ANKZ | RADIO FREQUENCY RATING | 2.0 GIGAHERTZ MINIMUM AND 4.0 GIGAHERTZ MAXIMUM |
APGF | DESIGN TYPE | BIDIRECTIONAL OR UNIDIRECTIONAL |
APQB | UNIT TYPE | COAXIAL LINE OR TRANSMISSION LINE |
BGPS | VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.2 TO 1 AT 2 TO 4 GHZ |
BGPY | TERMINAL FITTING NAME | TNC FEMALE RECEPTACLE |
BGQC | TERMINAL FITTING USAGE DESIGN | MAIN LINE AND SECONDARY LINE |
![]() |