Mfg Part Number: 2562A13 | Manufacturer: Interstate Electronics Corporation | NSN : 6610-00-961-1971 |
Item Name : transmitter angle of attack | CAGE Code : 07421 | FSC : 6610 Flight Instruments |
MRC | Criteria | Characteristic |
---|---|---|
AXGY | Mounting Method | FLANGE |
ELEC | Voltage In Volts | 115 |
RDAL | Reference Data And Literature | T.O.5F10-4-11-4 |
BBKB | Heating Element Phase | SINGLE |
BBTF | Heating Element Voltage In Volts | 115 |
BBTR | Total Angular Rotation In Deg | 60 |
BBTW | Operating Velocity Range | NOT RATED |
ABYA | Attachment Device Type | DOWEL PIN |
BBJY | Electrical Heating Element | PROVIDED |
BBJZ | Heating Element Current Type | AC |
BBTG | Heating Element Wattage In Watts | 270 |
BBTQ | Sensing Element Type | VANE |
FREQ | Frequency In Hertz | 400 |
FAAZ | Phase | SINGLE |
MRC | Decoded Requirement | Clear Text Reply |
ABMK | Overall Width | 4.000 INCHES NOMINAL |
AKVR | Transducer Quantity | 2 |
AKVS | Transducer Type | SYNCHRO |
ACDC | Current Type | AC |
ABHP | Overall Length | 7.200 INCHES NOMINAL |
BBKC | Heating Element Frequency In Hertz | 400 |
BBTS | Accuracy Rating In Deg | 0.3 |
ABKW | Overall Height | 6.020 INCHES NOMINAL |
AAGB | Operating Temp Range In Deg Celsius | -0.580645161 |
AEZD | Switch | NOT INCLUDED |
![]() |