Mfg Part Number: 1B1000-1G-RR-901 | Alternate P/N: 1B10001GRR901 | Manufacturer: Avionic Instruments Llc |
NSN : 6130-01-378-8271 | Item Name : inverter power static | CAGE Code : 10933 |
FSC : 6130 Converters Electrical Nonrotating |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-378-8271 Item Description: INVERTER,POWER,STATIC | 6130 | 013788271 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1B1000-1G-RR-901 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET SINGLE POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -55.0/+71.0 DEG CELSIUS |
CWHM | INPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
![]() |